MET ONE 3411 Portable with Gas Calibration

2088800-05


Part of the MET ONE Facility Monitoring System. MET ONE 3411 Portable Air Particle Counter
 

Especificaciones

Platform APC Instruments
Performance ISO 21501-4 unit-to-unit accuracy & reproducibility
Light Source Helium neon laser
Coincidence Loss % at 1,765,000 particles/m3 (per ISO 21501-4 method)
Interfaces & Protocols RS232, RS-485, USB Client (v1.1), USB Host (v1.1), Modbus TCP, Modbus RTU, Serial FX, Ethernet 802.3
Data Storage 5000 samples
Battery Lithium ion smart battery (rechargeable, ejectable & hot-swappable)
Battery Operating Time 3 hours (minimum)
Battery Recharge Time 6.75 hours (minimum) - 10 hours (maximum)
Pump Type Air vacuum, rated for continuous use
Zero Count ISO 21501-4 & JIS B 9921 (1 count or less in 5 minutes; 95% Upper Confidence Limit)
Counting Efficiency 50% at 0.1 μm (100% for particles > 0.15 μm per ISO 21501-4 & JIS B 9921)
Count Alarms, Display & Cycles User-defined alarm counts, Raw counts: N/CF, N/CM, N/L in cumulative or differential mode
Label Locations ID: 0 to 999; NAME: Alphanumeric (appears on printout)
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 0°C to 40°C, Storage temperature range: -40°C to 50°C
Humidity Restrictions 10%-90% relative humidity (non-condensing)
Power Requirements 24 VDC; 3.2A with 100-240 VAC; 50/60 Hz adapter (included in ship kit)
Operating System Windows® CE
Display Color 1/4 VGA TFT touch screen
Weight 15.90|kg (without battery)
Width 33.00|cm / 12.992125984252|in
Depth 56.00|cm / 22.0472440944882|in
Height 23.00|cm / 9.05511811023622|in
Color Silver

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.